The clinical effectiveness and cost-effectiveness of heated humidified high-flow nasal cannula compared with usual care for preterm infants: systematic review and economic evaluation



Fleeman, N ORCID: 0000-0002-4637-9779, Mahon, J, Bates, V, Dickson, R ORCID: 0000-0003-1416-0913, Dundar, Y, Dwan, K, Ellis, L, Kotas, E, Richardson, M ORCID: 0000-0002-7097-8704, Shah, P
et al (show 1 more authors) (2016) The clinical effectiveness and cost-effectiveness of heated humidified high-flow nasal cannula compared with usual care for preterm infants: systematic review and economic evaluation. HEALTH TECHNOLOGY ASSESSMENT, 20 (30). pp. 1-67.

[img] Text
HHHFNC_report_re-submitted_post-editorial_1.pdf - Author Accepted Manuscript

Download (1MB)

Abstract

Background Respiratory problems are one of the most common causes of morbidity in preterm infants and may be treated with several modalities for respiratory support such as nasal continuous positive airway pressure (NCPAP) or nasal intermittent positive-pressure ventilation. The heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity in clinical practice. Objectives To address the clinical effectiveness of HHHFNC compared with usual care for preterm infants we systematically reviewed the evidence of HHHFNC with usual care following ventilation (the primary analysis) and with no prior ventilation (the secondary analysis). The primary outcome was treatment failure defined as the need for reintubation (primary analysis) or intubation (secondary analysis). We also aimed to assess the cost-effectiveness of HHHFNC compared with usual care if evidence permitted. Data sources The following databases were searched: MEDLINE (2000 to 12 January 2015), EMBASE (2000 to 12 January 2015), The Cochrane Library (issue 1, 2015), ISI Web of Science (2000 to 12 January 2015), PubMed (1 March 2014 to 12 January 2015) and seven trial and research registers. Bibliographies of retrieved citations were also examined. Review methods Two reviewers independently screened all titles and abstracts to identify potentially relevant studies for inclusion in the review. Full-text copies were assessed independently. Data were extracted and assessed for risk of bias. Summary statistics were extracted for each outcome and, when possible, data were pooled. A meta-analysis was only conducted for the primary analysis, using fixed-effects models. An economic evaluation was planned. Results Clinical evidence was derived from seven randomised controlled trials (RCTs): four RCTs for the primary analysis and three RCTs for the secondary analysis. Meta-analysis found that only for nasal trauma leading to a change of treatment was there a statistically significant difference, favouring HHHFNC over NCPAP [risk ratio (RR) 0.21, 95% confidence interval (CI) 0.10 to 0.42]. For the following outcomes, there were no statistically significant differences between arms: treatment failure (reintubation < 7 days; RR 0.76, 95% CI 0.54 to 1.09), bronchopulmonary dysplasia (RR 0.92, 95% CI 0.72 to 1.17), death (RR 0.56, 95% CI 0.22 to 1.44), pneumothorax (RR 0.33, 95% CI 0.03 to 3.12), intraventricular haemorrhage (grade ≥ 3; RR 0.41, 95% CI 0.15 to 1.15), necrotising enterocolitis (RR 0.41, 95% CI 0.15 to 1.14), apnoea (RR 1.08, 95% CI 0.74 to 1.57) and acidosis (RR 1.16, 95% CI 0.38 to 3.58). With no evidence to support the superiority of HHHFNC over NCPAP, a cost-minimisation analysis was undertaken, the results suggesting HHHFNC to be less costly than NCPAP. However, this finding is sensitive to the lifespan of equipment and the cost differential of consumables. Limitations There is a lack of published RCTs of relatively large-sized populations comparing HHHFNC with usual care; this is particularly true for preterm infants who had received no prior ventilation. Conclusions There is a lack of convincing evidence suggesting that HHHFNC is superior or inferior to usual care, in particular NCPAP. There is also uncertainty regarding whether or not HHHFNC can be considered cost-effective. Further evidence comparing HHHFNC with usual care is required. Study registration This review is registered as PROSPERO CRD42015015978. Funding The National Institute for Health Research Health Technology Assessment programme.

Item Type: Article
Uncontrolled Keywords: Humans, Respiratory Distress Syndrome, Newborn, Treatment Outcome, Catheterization, Peripheral, Continuous Positive Airway Pressure, Infant, Newborn, Infant, Premature, Cost-Benefit Analysis, Technology Assessment, Biomedical, Randomized Controlled Trials as Topic, Hot Temperature, Cannula
Depositing User: Symplectic Admin
Date Deposited: 15 Sep 2016 11:26
Last Modified: 21 Aug 2023 21:25
DOI: 10.3310/hta20300