Evaluation of the starting point of the Lombard Effect.



Bottalico, Pasquale ORCID: 0000-0002-7394-4796, Passione, Ivano Ipsaro, Graetzer, Simone ORCID: 0000-0003-1446-5637 and Hunter, Eric J ORCID: 0000-0001-5571-464X
(2017) Evaluation of the starting point of the Lombard Effect. Acta acustica united with acustica : the journal of the European Acoustics Association (EEIG), 103 (1). pp. 169-172.

[img] Text
bottali.pdf - Author Accepted Manuscript

Download (590kB)

Abstract

Speakers increase their vocal effort when their communication is disturbed by noise. This adaptation is termed the Lombard effect. The aim of the present study was to determine whether this effect has a starting point. Hence, the effects of noise at levels between 20 and 65 dB(A) on vocal effort (quantified by sound pressure level) and on both perceived noise disturbance and perceived vocal discomfort were evaluated. Results indicate that there is a Lombard effect change-point at a background noise level (Ln) of 43.3 dB(A). This change-point is anticipated by noise disturbance, and is followed by a high magnitude of vocal discomfort.

Item Type: Article
Depositing User: Symplectic Admin
Date Deposited: 15 Dec 2016 08:51
Last Modified: 19 Jan 2023 07:24
DOI: 10.3813/aaa.919043
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3004889