Pre-Implantation Balloon Aortic Valvuloplasty and Clinical Outcomes Following Transcatheter Aortic Valve Implantation: A Propensity Score Analysis of the UK Registry.



Martin, Glen P, Sperrin, Matthew, Bagur, Rodrigo, de Belder, Mark A, Buchan, Iain ORCID: 0000-0003-3392-1650, Gunning, Mark, Ludman, Peter F and Mamas, Mamas A
(2017) Pre-Implantation Balloon Aortic Valvuloplasty and Clinical Outcomes Following Transcatheter Aortic Valve Implantation: A Propensity Score Analysis of the UK Registry. Journal of the American Heart Association, 6 (2). e004695-.

Access the full-text of this item by clicking on the Open Access link.

Abstract

BACKGROUND:Aortic valve predilation with balloon aortic valvuloplasty (BAV) is recommended before transcatheter aortic valve implantation (TAVI), despite limited data around the requirement of this preprocedural step and the potential risks of embolization. This study aimed to investigate the trends in practice and associations of BAV on short-term outcomes in the UK TAVI registry. METHODS AND RESULTS:Eleven clinical endpoints were investigated, including 30-day mortality, myocardial infarction, aortic regurgitation, valve dysfunction, and composite early safety. All endpoints were defined as per the VARC-2 definitions. Odd ratios of each endpoint were estimated using logistic regression, with data analyzed in balloon- and self-expandable valve subgroups. Propensity scores were calculated using patient demographics and procedural variables, which were included in the models of each endpoint to adjust for measured confounding. Between 2007 and 2014, 5887 patients met the study inclusion criteria, 1421 (24.1%) of whom had no BAV before TAVI valve deployment. We observed heterogeneity in the use of BAV nationally, both temporally and by center experience; rates of BAV in pre-TAVI workup varied between 30% and 97% across TAVI centers. All endpoints were similar between treatment groups in SAPIEN (Edwards Lifesciences Inc., Irvine, CA) valve patients. After correction for multiple testing, none of the endpoints in CoreValve (Medtronic, Minneapolis, MN) patients were significantly different between patients with or without predilation. CONCLUSIONS:Performing TAVI without predilation was not associated with adverse short-term outcomes post procedure, especially when using a balloon-expandable prosthesis. Randomized trials including different valve types are required to provide conclusive evidence regarding the utility of predilation before-TAVI.

Item Type: Article
Uncontrolled Keywords: Aortic Valve, Humans, Aortic Valve Stenosis, Postoperative Complications, Treatment Outcome, Registries, Morbidity, Survival Rate, Retrospective Studies, Aged, 80 and over, Female, Male, Propensity Score, Balloon Valvuloplasty, Transcatheter Aortic Valve Replacement, United Kingdom
Depositing User: Symplectic Admin
Date Deposited: 27 Mar 2019 11:49
Last Modified: 19 Jan 2023 00:55
DOI: 10.1161/JAHA.116.004695
Open Access URL: http://10.0.4.137/JAHA.%20116.004695
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3035101