Clinical Validation of the Automated Characterisation of Cone Size and Centre in Keratoconic Corneas



Lopes, Bernardo, Padmanabhan, Prema, Zhang, Haixia, Abass, Ahmed ORCID: 0000-0002-8622-4632, Eliasy, Ashkan ORCID: 0000-0002-4473-1900, Bandeira, Francisco, Bao, Fanjung, Bühren, Jens, Elmassry, Ahmed, Faria-Correia, Fernando
et al (show 7 more authors) (2021) Clinical Validation of the Automated Characterisation of Cone Size and Centre in Keratoconic Corneas. Journal of Refractive Surgery, 37 (6). 414-+.

[img] Text
JRS-2020-375_R1 new.pdf - Author Accepted Manuscript

Download (5MB) | Preview

Abstract

<h4>Purpose</h4>To evaluate an automated method for detecting the cone shape characteristics and to assess the cornea specialists' subjective variability of these measures using different maps.<h4>Methods</h4>Topographic images of the anterior and posterior surface of each eye were presented to 12 clinicians in two different types of map: tangential curvature and relative elevation to the best-fit sphere. They were asked to mark the cone center and its boundaries in the two maps without knowing that they belonged to the same patient. The results between the maps were compared to assess the subjective variability dependent on the map type and the automated method was compared against both estimations to assess its accuracy.<h4>Results</h4>Considering the results of anterior and posterior surfaces, there was low agreement between the cone center estimations using different types of maps for 10 of the 12 cases (<i>P</i> < .05), whereas the comparison between the automated method and the two map estimations did not show differences in 11 of the 12 cases (<i>P</i> > .05). There was high variability, up to 55%, among clinicians' estimations of the cone area. The results of the automated method were within the range of the expert's estimations.<h4>Conclusions</h4>An objective, mathematically derived method of determining morphological dimensions of the cone was consistent with clinicians' evaluations. Although there was high variability among the experts' subjective estimates, which were highly influenced by the type of map, the objective method provided a reliable evaluation of the keratoconus shape independent of maps or color scale. <b>[<i>J Refract Surg</i>. 2021;37(6):414-421.]</b>.

Item Type: Article
Uncontrolled Keywords: Cornea, Humans, Keratoconus, Corneal Topography
Depositing User: Symplectic Admin
Date Deposited: 16 Dec 2020 12:25
Last Modified: 04 Jul 2023 15:12
DOI: 10.3928/1081597X-20210315-03
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3110479