Aerosol and splatter generation with rotary handpieces used in restorative and orthodontic dentistry: a systematic review



Al-yaseen, Waraf, Jones, Rhiannon, McGregor, Scott, Wade, William, Gallagher, Jennifer, Harris, Rebecca ORCID: 0000-0002-5891-6826, Johnson, Ilona, Kc, Sukriti, Robertson, Mark and Innes, Nicola
(2022) Aerosol and splatter generation with rotary handpieces used in restorative and orthodontic dentistry: a systematic review. BDJ OPEN, 8 (1). 26-.

Access the full-text of this item by clicking on the Open Access link.
[img] PDF
Aerosol and splatter generation with rotary handpieces used in restorative and orthodontic dentistry a systematic review.pdf - Published version

Download (1MB) | Preview

Abstract

<h4>Introduction</h4>The COVID-19 pandemic has caused major disruptions in dental care globally, in part due to the potential for contaminated aerosol to be generated by dental activities. This systematic review assesses the literature for changes in aerosol-contamination levels when rotary instruments are used, (1) as distance increases from patient's mouth; (2) as time passes after the procedure; and (3) when using different types of handpieces.<h4>Methods</h4>The review methods and reporting are in line with PRISMA statements. A structured search was conducted over five platforms (September 2021). Studies were assessed independently by two reviewers. To be eligible studies had to assess changes in levels of aerosol contamination over different distances, and time points, with rotary hand instruments. Studies' methodologies and the sensitivity of the contamination-measurement approaches were evaluated. Results are presented descriptively.<h4>Results</h4>From 422 papers identified, 23 studies were eligible. All investigated restorative procedures using rotary instruments and one study additionally looked at orthodontic bracket adhesive material removal. The results suggest contamination is significantly reduced over time and distance. However, for almost all studies that investigated these two factors, the sizes of the contaminated particles were not considered, and there were inconclusive findings regarding whether electric-driven handpieces generate lower levels of contaminated particles.<h4>Conclusion</h4>Aerosol contamination levels reduce as distances, and post-procedure times increase. However, there was sparce and inconsistent evidence on the clearing time and no conclusions could be drawn. High-speed handpieces produce significantly higher levels of contamination than slow-speed ones, and to a lesser extent, micro-motor handpieces. However, when micro-motor handpieces were used with water, the contamination levels rose and were similar to high-speed handpiece contamination levels.

Item Type: Article
Uncontrolled Keywords: Dental/Oral and Craniofacial Disease, Bioengineering
Divisions: Faculty of Health and Life Sciences
Faculty of Health and Life Sciences > Institute of Population Health
Depositing User: Symplectic Admin
Date Deposited: 08 Feb 2023 16:09
Last Modified: 15 Mar 2024 02:37
DOI: 10.1038/s41405-022-00118-4
Open Access URL: https://doi.org/10.1038/s41405-022-00118-4
Related URLs: