Multicenter Diagnostic Evaluation of OnSite COVID-19 Rapid Test (CTK Biotech) among Symptomatic Individuals in Brazil and the United Kingdom



Thompson, Caitlin, Torres, Pablo Munoz, Kontogianni, Konstantina, Byrne, Rachel, Noguera, Saidy Vasconez, Luna-Muschi, Alessandra, Marchi, Ana Paula, Andrade, Pamela S, Barboza, Antonio dos Santos, Nishikawara, Marli
et al (show 6 more authors) (2023) Multicenter Diagnostic Evaluation of OnSite COVID-19 Rapid Test (CTK Biotech) among Symptomatic Individuals in Brazil and the United Kingdom. MICROBIOLOGY SPECTRUM, 11 (3). e0504422-.

Access the full-text of this item by clicking on the Open Access link.

Abstract

The COVID-19 pandemic has given rise to numerous commercially available antigen rapid diagnostic tests (Ag-RDTs). To generate and to share accurate and independent data with the global community requires multisite prospective diagnostic evaluations of Ag-RDTs. This report describes the clinical evaluation of the OnSite COVID-19 rapid test (CTK Biotech, CA, USA) in Brazil and the United Kingdom. A total of 496 paired nasopharyngeal (NP) swabs were collected from symptomatic health care workers at Hospital das Clínicas in São Paulo, Brazil, and 211 NP swabs were collected from symptomatic participants at a COVID-19 drive-through testing site in Liverpool, United Kingdom. Swabs were analyzed by Ag-RDT, and results were compared to quantitative reverse transcriptase PCR (RT-qPCR). The clinical sensitivity of the OnSite COVID-19 rapid test in Brazil was 90.3% (95% confidence interval [CI], 75.1 to 96.7%) and in the United Kingdom was 75.3% (95% CI, 64.6 to 83.6%). The clinical specificity in Brazil was 99.4% (95% CI, 98.1 to 99.8%) and in the United Kingdom was 95.5% (95% CI, 90.6 to 97.9%). Concurrently, analytical evaluation of the Ag-RDT was assessed using direct culture supernatant of SARS-CoV-2 strains from wild-type (WT), Alpha, Delta, Gamma, and Omicron lineages. This study provides comparative performance of an Ag-RDT across two different settings, geographical areas, and populations. Overall, the OnSite Ag-RDT demonstrated a lower clinical sensitivity than claimed by the manufacturer. The sensitivity and specificity from the Brazil study fulfilled the performance criteria determined by the World Health Organization, but the performance obtained from the UK study failed to do. Further evaluation of Ag-RDTs should include harmonized protocols between laboratories to facilitate comparison between settings. <b>IMPORTANCE</b> Evaluating rapid diagnostic tests in diverse populations is essential to improving diagnostic responses as it gives an indication of the accuracy in real-world scenarios. In the case of rapid diagnostic testing within this pandemic, lateral flow tests that meet the minimum requirements for sensitivity and specificity can play a key role in increasing testing capacity, allowing timely clinical management of those infected, and protecting health care systems. This is particularly valuable in settings where access to the test gold standard is often restricted.

Item Type: Article
Uncontrolled Keywords: COVID-19, RDT, diagnostics
Divisions: Faculty of Health and Life Sciences
Faculty of Health and Life Sciences > Institute of Systems, Molecular and Integrative Biology
Depositing User: Symplectic Admin
Date Deposited: 26 Mar 2024 11:14
Last Modified: 26 Mar 2024 16:33
DOI: 10.1128/spectrum.05044-22
Open Access URL: https://doi.org/10.1128/spectrum.05044-22
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3179978