Lawman, S ORCID: 0000-0003-2695-4366, Dong, Y, Williams, BM ORCID: 0000-0001-5930-287X, Romano, V ORCID: 0000-0002-5148-7643, Kaye, S ORCID: 0000-0003-0390-0592, Harding, SP ORCID: 0000-0003-4676-1158, Willoughby, C, Shen, YC ORCID: 0000-0002-8915-1993 and Zheng, Y ORCID: 0000-0002-7873-0922
(2016)
High Resolution Corneal and Single Pulse Imaging with Line Field Spectral Domain Optical Coherence Tomography.
Optics Express, 24 (11).
pp. 12395-12405.
Text
2016-OE-OCT.pdf - Published version Download (1MB) |
|
Atom XML (admin)
2017-05-12T11:19:10Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T12:18:09Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T13:17:34Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T14:17:25Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T15:17:36Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T16:17:46Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T17:17:30Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T18:17:55Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T19:17:42Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T20:17:45Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T21:18:03Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T22:18:42Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-12T23:23:20Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T01:18:49Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T02:18:27Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T03:18:33Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T04:33:30Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T05:18:19Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T06:17:43Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T07:18:08Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T08:18:25Z.atom - Unspecified Download (0B) |
|
Atom XML (admin)
2017-05-13T09:17:39Z.atom - Unspecified Download (0B) |
Abstract
We report the development of a Spectral Domain Line Field Optical Coherence Tomography (LF-OCT) system, using a broad bandwidth and spatial coherent Super-Continuum (SC) source. With conventional quasi-Continuous Wave (CW) setup we achieve axial resolutions up to 2.1 μm in air and 3D volume imaging speeds up to 213 kA-Scan/s. Furthermore, we report the use of a single SC pulse, of 2 ns duration, to temporally gate an OCT B-Scan image of 70 A-Scans. This is the equivalent of 35 GA-Scans/s. We apply the CW setup for high resolution imaging of the fine structures of a human cornea sample ex-vivo. The single pulse setup is applied to imaging of a coated pharmaceutical tablet. The fixed pattern noise due to spectral noise is removed by subtracting the median magnitude A-Scan. We also demonstrate that the Fourier phase can be used to remove aberration caused artefacts.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Biomedical Imaging, Bioengineering, Clinical Research |
Depositing User: | Symplectic Admin |
Date Deposited: | 02 Jun 2016 10:01 |
Last Modified: | 15 Mar 2024 14:48 |
DOI: | 10.1364/OE.24.012395 |
Related URLs: | |
URI: | https://livrepository.liverpool.ac.uk/id/eprint/3001477 |