Studying the Pharmaceutical Film Coating Process with Terahertz Sensing, Optical Coherence Tomography and Numerical Modelling



Lin, Hungyen, Dong, Yue, Pei, Chunlei, Williams, Bryan M ORCID: 0000-0001-5930-287X, Markl, Daniel, Zheng, Yalin ORCID: 0000-0002-7873-0922, Elliott, James A, Shen, Yaochun ORCID: 0000-0002-8915-1993 and Zeitler, J Axel
(2016) Studying the Pharmaceutical Film Coating Process with Terahertz Sensing, Optical Coherence Tomography and Numerical Modelling. In: 2016 41st International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz), 2016-9-25 - 2016-9-30, Copenhagen.

[img] Text
PID4360479.pdf - Author Accepted Manuscript

Download (342kB)

Abstract

Terahertz in-line sensing was successfully demonstrated on a production scale setting for measuring the coating thickness of individual pharmaceutical tablets during the film coating process. This paper reports on our recent research progress to combine terahertz in-line sensing, optical coherence tomography and numerical modelling in a lab scale setting to better understand the pharmaceutical film coating process.

Item Type: Conference or Workshop Item (Unspecified)
Depositing User: Symplectic Admin
Date Deposited: 15 Feb 2017 11:19
Last Modified: 15 Mar 2024 10:18
DOI: 10.1109/irmmw-thz.2016.7758595
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3005695