Diaz Delgado, Oscar Bautista, Louro, Luis Filipe, Rocchigiani, Guido
ORCID: 0000-0002-3742-7636, Verin, Ranieri, Humphreys, William
ORCID: 0000-0001-8945-7207, Senior, Mark
ORCID: 0000-0002-9425-9261 and Campagna, Ivo
(2021)
Ultrasound-guided erector spinae plane block in horses: a cadaver study
VETERINARY ANAESTHESIA AND ANALGESIA, 48 (4).
pp. 577-584.
ISSN 1467-2987, 1467-2995
|
Text
ESP block paper_VAA-20-0082.Main-Doc.EiC.docx - Author Accepted Manuscript Download (52kB) |
Abstract
Objectives: To describe dye distribution and spinal nerve involvement after a simulated erector spinae plane (ESP) block performed on fresh equine cadavers. Study design: Experimental cadaver study. Animals: A group of 11 adult equine cadavers. Methods: The spinal region surrounding the sixteenth thoracic vertebra (Th16) of one cadaver was removed and underwent magnetic resonance imaging. In 10 adult equine cadavers [body weight, 549 ± 58 kg (mean ± standard deviation)], 0.2 mL kg–1 of a 50:1 2% lidocaine/dye solution was injected bilaterally (n = 20 injections) into the fascial plane between the transverse process of Th16 and the erector spinae muscles. An in-plane ultrasound-guided technique with a convex transducer was used to guide injection. Dissection was performed immediately following injection. The craniocaudal and lateral extent of dye distribution was measured (cm) and the number of vertebral bodies involved were counted (n = 20). Abdominal and thoracic cavities as well as the epidural space were also examined for presence of dye (yes/no) (n = 20). Further dissection was performed to evaluate if staining of the dorsal and ventral rami of the spinal nerves and sympathetic chain occurred (n = 14). Results: The thoracolumbar fascia was stained in 17/20 (85%) injections and three injections terminated intramuscularly. Multisegmental staining of the dorsal rami was observed in the 14 injections in which staining was evaluated. Ventral rami staining was observed in 3/14 injections where staining was evaluated. Epidural migration was observed in 4/20 (20%) injections. No evidence of dye was found in the thoracic and abdominal cavities or on the sympathetic chain. Conclusions and clinical relevance: The ESP block may prove beneficial to desensitize structures innervated by the dorsal rami of the thoracic spinal nerves. Further investigation is necessary to evaluate complications caused by epidural contamination.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | back pain, dorsal root, equine, nerve block, regional anaesthesia, spinal nerves |
| Divisions: | Faculty of Health & Life Sciences Faculty of Health & Life Sciences > Inst. Infection, Vet & Ecological Sciences |
| Depositing User: | Symplectic Admin |
| Date Deposited: | 07 Oct 2021 15:05 |
| Last Modified: | 23 May 2026 05:51 |
| DOI: | 10.1016/j.vaa.2020.11.009 |
| Related Websites: | |
| URI: | https://livrepository.liverpool.ac.uk/id/eprint/3139627 |
| Disclaimer: | The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate. |
Altmetric
Altmetric