Ye, Yufeng, Li, Yi, Zhu, Zehui, Abu Said, Anas Ziad Masoud, Nguelemo Mayopa, Kevin, Akiti, Stephen, Huang, Chengyi, Lopes, Bernardo T, Eliasy, Ashkan ORCID: 0000-0002-4473-1900, Miao, Yuanyuan et al (show 5 more authors)
(2021)
Effect of Mydriasis-Caused Intraocular Pressure Changes on Corneal Biomechanical Metrics.
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 9.
751628-.
ISSN 2296-4185, 2296-4185
Text
Modified Manuscript2.pdf - Author Accepted Manuscript Download (444kB) | Preview |
Abstract
<b>Purpose:</b> To evaluate the dependence of biomechanical metrics on intraocular pressure (IOP). <b>Methods:</b> 233 refractive surgery patients were included in this study-all were examined 3 times with the Corvis ST before and after dilation, and the differences (∆) in the main device parameters were assessed. The data collected included the biomechanically corrected IOP (bIOP), the central corneal thickness (CCT), and six dynamic corneal response (DCR) parameters, namely DA, DARatio2mm, IIR, SP-A1, CBI, and SSI. Participants were divided into three groups according to the changes in patients' bIOP after mydriasis. <b>Results:</b> Intra-operator repeatability was generally high in most of the DCR parameters obtained before and after dilation. The mean changes in bIOP and CCT after dilation were -0.12 ± 1.36 mmHg and 1.95 ± 5.23 μm, respectively. Only ∆DARatio2mm, ∆IIR, and ∆CBI exhibited a statistically significant correlation with ∆CCT (<i>p</i> < 0.05). The changes in all DCR parameters, especially ∆DA and ∆SP-A1 were also correlated with ∆bIOP (<i>p</i> < 0.01)-a 1-mmHg change in bIOP was associated, on average, with 5.612 and -0.037 units of change in SP-A1 and DA, respectively. In contrast, the weakest correlation with ∆bIOP was exhibited by ∆SSI. <b>Conclusion:</b> Most corneal DCR parameters, provided by the Corvis ST, were correlated with IOP, and more weakly with CCT. Changes experienced in CCT and IOP should therefore be considered in studies on corneal biomechanics and how it is affected by disease progression and surgical or medical procedures.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | biomechanical metrics, intraocular pressure, mydriasis, stiffness parameter at first applanation, stress-strain index |
Divisions: | Faculty of Science and Engineering > School of Engineering |
Depositing User: | Symplectic Admin |
Date Deposited: | 26 Oct 2021 15:36 |
Last Modified: | 06 Dec 2024 20:15 |
DOI: | 10.3389/fbioe.2021.751628 |
Related URLs: | |
URI: | https://livrepository.liverpool.ac.uk/id/eprint/3141730 |