Abstract
AbstractAccurate quantification of blood creatinine is important to estimate the glomerular filtration rate. Existing techniques using liquid chromatography tandem mass spectrometry (LC–MS/MS) have a high accuracy and eliminate most interferences encountered in routine enzymatic and Jaffé methods. However, they require laborious and time-consuming sample treatment and data acquisition. The aim of this study is to develop a fast and simple method to enable a direct analysis of whole blood creatinine with performance measures that are comparable to conventional LC–MS/MS. 5μL whole blood is formed as a three-dimensional spheroid on hydrophobic silanized paper substrates which then undergoes paper-spray ionization—tandem mass spectrometry (PSI–MS/MS). The method is validated using real human samples and compared with LC–MS/MS. PSI–MS/MS whole blood analysis exhibited a lower limit of quantification of 2.5 μg/mL, precision ≤ 6.3%, recovery in the range of 88–94% and excellent linearity (R2 > 0.99; 2.5—20 μg/mL) covering the normal range for creatinine levels. Creatinine levels were comparable to those measured by LC–MS/MS with small deviations of less than 0.3 μg/mL. This simple, fast and accurate microsampling technique for direct analysis of creatinine from whole blood shows promise for routine clinical screening and monitoring. This approach can be readily extended for other analytes of interest and, due to inherent advantages relating to cost, storability, speed, and simplicity, it can be especially advantageous for use in resource-limited settings.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Humans, Creatinine, Glomerular Filtration Rate, Chromatography, Liquid, Chromatography, High Pressure Liquid, Reproducibility of Results, Tandem Mass Spectrometry |
| Divisions: | Faculty of Science & Engineering > School of Electrical Engineering, Electronics and Computer Science |
| Depositing User: | Symplectic Admin |
| Date Deposited: | 23 Aug 2022 07:12 |
| Last Modified: | 16 Jun 2026 10:28 |
| DOI: | 10.1038/s41598-022-18365-8 |
| Open Access URL: | https://www.nature.com/articles/s41598-022-18365-8 |
| Related Websites: | |
| URI: | https://livrepository.liverpool.ac.uk/id/eprint/3162001 |
| Disclaimer: | The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate. |
Altmetric
Altmetric