Validation of extracorporeal membrane oxygenation mortality prediction and severity of illness scores in an international COVID-19 cohort.



Shah, Neel, Xue, Bing, Xu, Ziqi, Yang, Hanqing, Marwali, Eva, Dalton, Heidi, Payne, Philip PR, Lu, Chenyang, Said, Ahmed S and ISARIC Clinical Characterisation Group
(2023) Validation of extracorporeal membrane oxygenation mortality prediction and severity of illness scores in an international COVID-19 cohort. Artificial organs, 47 (9). pp. 1490-1502. ISSN 0160-564X, 1525-1594

[thumbnail of ISARIC ECMO scores - clean 31523.docx] Text
ISARIC ECMO scores - clean 31523.docx - Author Accepted Manuscript

Download (124kB)

Abstract

<h4>Background</h4>Veno-venous extracorporeal membrane oxygenation (V-V ECMO) is a lifesaving support modality for severe respiratory failure, but its resource-intensive nature led to significant controversy surrounding its use during the COVID-19 pandemic. We report the performance of several ECMO mortality prediction and severity of illness scores at discriminating survival in a large COVID-19 V-V ECMO cohort.<h4>Methods</h4>We validated ECMOnet, PRESET (PREdiction of Survival on ECMO Therapy-Score), Roch, SOFA (Sequential Organ Failure Assessment), APACHE II (acute physiology and chronic health evaluation), 4C (Coronavirus Clinical Characterisation Consortium), and CURB-65 (Confusion, Urea nitrogen, Respiratory Rate, Blood Pressure, age >65 years) scores on the ISARIC (International Severe Acute Respiratory and emerging Infection Consortium) database. We report discrimination via Area Under the Receiver Operative Curve (AUROC) and Area under the Precision Recall Curve (AURPC) and calibration via Brier score.<h4>Results</h4>We included 1147 patients and scores were calculated on patients with sufficient variables. ECMO mortality scores had AUROC (0.58-0.62), AUPRC (0.62-0.74), and Brier score (0.286-0.303). Roch score had the highest accuracy (AUROC 0.62), precision (AUPRC 0.74) yet worst calibration (Brier score of 0.3) despite being calculated on the fewest patients (144). Severity of illness scores had AUROC (0.52-0.57), AURPC (0.59-0.64), and Brier Score (0.265-0.471). APACHE II had the highest accuracy (AUROC 0.58), precision (AUPRC 0.64), and best calibration (Brier score 0.26).<h4>Conclusion</h4>Within a large international multicenter COVID-19 cohort, the evaluated ECMO mortality prediction and severity of illness scores demonstrated inconsistent discrimination and calibration highlighting the need for better clinically applicable decision support tools.

Item Type: Article
Uncontrolled Keywords: ISARIC Clinical Characterisation Group
Divisions: Faculty of Health & Life Sciences
Faculty of Health & Life Sciences > Inst. Infection, Vet & Ecological Sciences
Faculty of Health & Life Sciences > Inst. Population Health
Depositing User: Symplectic Admin
Date Deposited: 05 Sep 2024 08:33
Last Modified: 07 Dec 2024 23:12
DOI: 10.1111/aor.14542
Related Websites:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3172446
Disclaimer: The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate.