Numerical analysis of potential failure modes in shear walls of the tunnel form concrete system: Performance-based approach



Mohsenian, V and Di-Sarno, L
(2024) Numerical analysis of potential failure modes in shear walls of the tunnel form concrete system: Performance-based approach Engineering Structures, 303. 117494-. ISSN 0141-0296, 1873-7323

[thumbnail of Modified Manuscript-final version.docx] Text
Modified Manuscript-final version.docx - Author Accepted Manuscript
Available under License Creative Commons Attribution.

Download (2MB)

Abstract

Similar to other structural systems, the nonlinear modeling process of the tunnel-form concrete system necessitates an understanding of the potential failure modes in its primary lateral load-bearing members. With the identification of failure modes in the elements, deformation-control actions, force-control actions and deformation parameters are determined, making the analysis/design process straightforward. Given the unique characteristics of the tunnel-form concrete system, the applicability of design requirements and assumptions proposed for other similar systems for this structural system remains uncertain. In this study, to assess the potential failure modes of the walls of the system, two different modeling scenarios were utilized, employing pushover and time-history analyses. Within the scope of the studied 5- and 10-story buildings and the adopted assumptions, the results revealed that in the walls, shear is controlled by deformation and bending is force-control. In the incremental analysis, the bending failure mode of the walls (reaching yielding in vertical rebars) was estimated to be almost 10% higher than that of the shear failure mode (achieving an immediate occupancy limit). In the time-history analysis, under the design hazard level (475-year return period), the shear strain in the walls exceeded 13 times the strain at the onset of nonlinear shear behavior. This is because the wall sections still retained sufficient flexural-axial capacity and, contrary to code-based predictions, remained far from the flexural failure mode. The investigations further demonstrated that shear failure in the system was sufficiently ductile and capable of adequately absorbing and dissipating seismic input energy.

Item Type: Article
Uncontrolled Keywords: Tunnel -form concrete system, Reinforced concrete wall failure mode, Deformation -control action, Force -control action, Energy dissipation
Divisions: Faculty of Science & Engineering > School of Engineering
Depositing User: Symplectic Admin
Date Deposited: 20 Feb 2024 08:23
Last Modified: 23 May 2026 08:25
DOI: 10.1016/j.engstruct.2024.117494
Related Websites:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3178788
Disclaimer: The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate.