Debevc, J, Franks, M, Hiti, B, Kraemer, U, Kramberger, G, Mandic, I, Marco-Hernandez, R, Nobels, DJL, Powell, S, Sonneveld, J et al (show 4 more authors)
(2024)
Measurements of time resolution of the RD50-MPW2 DMAPS prototype using TCT and 90Sr
JOURNAL OF INSTRUMENTATION, 19 (5).
p05068-.
ISSN 1748-0221, 1748-0221
Abstract
Results in this paper present an in-depth study of time resolution for active pixels of the RD50-MPW2 prototype CMOS particle detector. Measurement techniques employed include Backside- and Edge-TCT configurations, in addition to electrons from a 90Sr source. A sample irradiated to 5 · 1014 n<inf>eq</inf>/cm2 was used to study the effect of radiation damage. Timing performance was evaluated for the entire pixel matrix and with positional sensitivity within individual pixels as a function of the deposited charge. Time resolution obtained with TCT is seen to be uniform throughout the pixel's central region with approx. 220 ps at 12 ke- of deposited charge, degrading at the edges and lower values of deposited charge. 90Sr measurements show a slightly worse time resolution as a result of delayed events coming from the peripheral areas of the pixel.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Particle tracking detectors (Solid-state detectors), Radiation-hard detectors, Solid state detectors |
| Divisions: | Faculty of Science & Engineering > School of Physical Sciences |
| Depositing User: | Symplectic Admin |
| Date Deposited: | 30 May 2024 15:02 |
| Last Modified: | 16 Jun 2026 16:57 |
| DOI: | 10.1088/1748-0221/19/05/P05068 |
| Open Access URL: | https://doi.org/10.1088/1748-0221/19/05/P05068 |
| Related Websites: | |
| URI: | https://livrepository.liverpool.ac.uk/id/eprint/3181879 |
| Disclaimer: | The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate. |

Altmetric