Abouyannis, Michael, Marriott, Amy E, Stars, Emma, Kitchen, Dianne P, Kitchen, Steve, Woods, Tim AL, Kreuels, Benno, Amuasi, John H, Monteiro, Wuelton Marcelo, Stienstra, Ymkje et al (show 5 more authors)
(2024)
Handheld point-of-care devices for snakebite coagulopathy: a scoping review.
Thrombosis and haemostasis, 125 (05).
pp. 405-420.
ISSN 0340-6245, 2567-689X
Abstract
Venom induced consumption coagulopathy (VICC) is a common complication of snakebite that is associated with hypofibrinogenaemia, bleeding, disability, and death. In remote tropical settings, where most snakebites occur, the 20-minute whole blood clotting test is used to diagnose VICC. Point-of-care (POC) coagulation devices could provide an accessible means of detecting VICC that is better standardised, quantifiable, and more accurate. In this scoping review, the mechanistic reasons that previously studied POC devices have failed in VICC are considered, and evidence-based recommendations are made to prioritise certain devices for clinical validation studies. Four small studies have evaluated a POC international normalised ratio (INR) device in patients with Australian Elapid, Daboia russelii and Echis carinatus envenoming. All of these studies used POC INR devices that rely on a thrombin substrate endpoint, which, unlike laboratory-based INR measurement, is known to underestimate INR in patients with hypofibrinogenaemia. Seventeen commercially available POC devices for measuring INR, activated clotting time (ACT), activated partial thromboplastin time (aPTT), fibrinogen, D-dimer, and fibrin(ogen) degradation products (FDP) have been reviewed. POC INR devices that detect fibrin clot formation, as well as a novel POC device that quantifies fibrinogen were identified, that show promise for use in patients with VICC. These devices could support more accurate allocation of antivenom, reduce the time to antivenom administration, and provide improved clinical trial outcome measurement instruments. There is an urgent need for these promising POC coagulation devices to be validated in prospective clinical snakebite studies.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | blood coagulation, point-of-care, snakebites, snake venoms |
| Dates: | Date Event 30 August 2024 Published 30 August 2024 Published Online 17 August 2024 Accepted |
| Depositing User: | Symplectic Admin |
| Date Deposited: | 10 Sep 2024 07:07 |
| Last Modified: | 09 Nov 2026 18:53 |
| DOI: | 10.1055/a-2407-1400 |
| Open Access URL: | https://www.thieme-connect.com/products/ejournals/... |
| Related Websites: | |
| URI: | https://livrepository.liverpool.ac.uk/id/eprint/3184385 |
| Disclaimer: | The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate. |

Altmetric
Altmetric