Handheld point-of-care devices for snakebite coagulopathy: a scoping review.



Abouyannis, Michael, Marriott, Amy E, Stars, Emma, Kitchen, Dianne P, Kitchen, Steve, Woods, Tim AL, Kreuels, Benno, Amuasi, John H, Monteiro, Wuelton Marcelo, Stienstra, Ymkje
et al (show 5 more authors) (2024) Handheld point-of-care devices for snakebite coagulopathy: a scoping review. Thrombosis and haemostasis, 125 (05). pp. 405-420. ISSN 0340-6245, 2567-689X

Access the full-text of this item by clicking on the Open Access link.

Abstract

Venom induced consumption coagulopathy (VICC) is a common complication of snakebite that is associated with hypofibrinogenaemia, bleeding, disability, and death. In remote tropical settings, where most snakebites occur, the 20-minute whole blood clotting test is used to diagnose VICC. Point-of-care (POC) coagulation devices could provide an accessible means of detecting VICC that is better standardised, quantifiable, and more accurate. In this scoping review, the mechanistic reasons that previously studied POC devices have failed in VICC are considered, and evidence-based recommendations are made to prioritise certain devices for clinical validation studies. Four small studies have evaluated a POC international normalised ratio (INR) device in patients with Australian Elapid, Daboia russelii and Echis carinatus envenoming. All of these studies used POC INR devices that rely on a thrombin substrate endpoint, which, unlike laboratory-based INR measurement, is known to underestimate INR in patients with hypofibrinogenaemia. Seventeen commercially available POC devices for measuring INR, activated clotting time (ACT), activated partial thromboplastin time (aPTT), fibrinogen, D-dimer, and fibrin(ogen) degradation products (FDP) have been reviewed. POC INR devices that detect fibrin clot formation, as well as a novel POC device that quantifies fibrinogen were identified, that show promise for use in patients with VICC. These devices could support more accurate allocation of antivenom, reduce the time to antivenom administration, and provide improved clinical trial outcome measurement instruments. There is an urgent need for these promising POC coagulation devices to be validated in prospective clinical snakebite studies.

Item Type: Article
Uncontrolled Keywords: blood coagulation, point-of-care, snakebites, snake venoms
Dates:
Date
Event
30 August 2024
Published
30 August 2024
Published Online
17 August 2024
Accepted
Depositing User: Symplectic Admin
Date Deposited: 10 Sep 2024 07:07
Last Modified: 09 Nov 2026 18:53
DOI: 10.1055/a-2407-1400
Open Access URL: https://www.thieme-connect.com/products/ejournals/...
Related Websites:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3184385
Disclaimer: The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate.