Investigation of the influence of relative wall area in plan and the role of their boundary elements in the seismic behavior of tunnel-form concrete system



Mohsenian, Vahid and Di-Sarno, Luigi
(2025) Investigation of the influence of relative wall area in plan and the role of their boundary elements in the seismic behavior of tunnel-form concrete system Journal of Building Engineering, 99. p. 111609. ISSN 2352-7102, 2352-7102

[thumbnail of JOBE -  In press 2024.pdf] Text
JOBE - In press 2024.pdf - Author Accepted Manuscript
Available under License Creative Commons Attribution.

Download (2MB) | Preview

Abstract

The provision of a minimum relative wall area equivalent to 3 % of the total plan area is one of the prescriptive requirements in design process of tunnel-form concrete systems, which is independent of seismic demands and often governs determination of the wall thickness. The high lateral stiffness and resistance of the tunnel-form concrete system generally encourage designers to disregard boundary elements in the walls. Although wall thickness and boundary elements are both essential factors in ensuring load-carrying capacity and ductility of walls, their specific effects within the tunnel-form concrete system have not been thoroughly examined to date. The motivation behind and the necessity of adhering to the prescriptive requirement for minimum relative wall area in tunnel-form plans remain ambiguous. In this study, aiming to address these concerns, 5- and 10-story tunnel-form buildings have been analyzed. Within the considered model range and adopted assumptions, the results indicate that the requirement for providing a minimum wall area in each plan direction is overly conservative and unnecessary. Without adhering to this requirement and solely following the minimum requirements of the reinforced concrete design code, a reduction of 12.9 m3 of concrete per story was achieved, with no observed change in the performance level of the system under design basis and maximum considered earthquakes. Furthermore, the investigations reveal that boundary elements of the walls do not significantly affect the seismic responses and behavior of the tunnel-form concrete system. Based on the results, even without boundary elements, the seismic reliability of the system for the immediate occupancy performance level in walls as the main lateral load-resisting elements was estimated to be 100 % under both design basis and maximum considered earthquakes.

Item Type: Article
Uncontrolled Keywords: Tunnel-form concrete system, Shear wall, Relative wall area, Boundary element, Coupling beam, Energy dissipation
Divisions: Faculty of Science & Engineering
Faculty of Science & Engineering > School of Engineering
Depositing User: Symplectic Admin
Date Deposited: 06 Jan 2025 09:33
Last Modified: 28 Feb 2026 17:13
DOI: 10.1016/j.jobe.2024.111609
Related Websites:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3189398
Disclaimer: The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate.