Alobaida, Muath, Lane, Deirdre A
ORCID: 0000-0002-5604-9378, Harrison, Stephanie L
ORCID: 0000-0002-8846-0946, Lip, Gregory YH
ORCID: 0000-0002-7566-1626 and Rowe, Fiona J
ORCID: 0000-0001-9210-9131
(2026)
Evaluating the use of vision-face-arm-speech-time in stroke admissions: A comparative study with national institutes of health stroke scale and orthoptist assessment in an emergency department
CLINICAL REHABILITATION, 40 (11).
2692155261450137-.
ISSN 0269-2155, 1477-0873
|
Text
alobaida-et-al-2026-evaluating-the-use-of-vision-face-arm-speech-time-in-stroke-admissions-a-comparative-study-with.pdf - Open Access published version Available under License Creative Commons Attribution. Download (929kB) | Preview |
Abstract
Objectives: Visual problems are common in acute stroke, however no standardised vision screening tool is routinely used in pre-hospital or emergency department settings. This study evaluated the V-FAST (vision-face-arm-speech-time) checklist for detecting visual impairment in patients admitted with suspected stroke. Design: Prospective, service evaluation study. Setting: One emergency department. Participants: About 282 consecutive patients with suspected stroke. Main measures: All patients were assessed with the National Institutes of Health Stroke Scale, V-FAST checklist, and reference standard orthoptic assessment. Main outcomes included visual impairment detection rates and diagnostic performance (sensitivity, specificity, predictive values, and agreement). Results: Of 282 screened patients (mean (SD) age 73 (11) years; 51.5% females), 158 (56.2%) had stroke confirmed. Among these, visual impairment was detected in 64.0% by orthoptists, 34.0% by the National Institutes of Health Stroke Scale (κ = 0.22), and 47.0% by V-FAST (κ=0.34). In FAST-positive strokes, National Institutes of Health Stroke Scale and V-FAST detected visual impairment in 83.3% and 76.0%, respectively; in FAST-negative strokes, detection was 16.7% and 24.0%, respectively, compared to orthoptic assessments. V-FAST showed better diagnostic performance than National Institutes of Health Stroke Scale, with sensitivity, specificity, positive/negative predictive values and kappa of 78.7%, 97.2%, 83.6%, 90.0%, and 0.79, respectively. Conclusion: The V-FAST checklist demonstrates fair agreement with orthoptist assessment and complements the National Institutes of Health Stroke Scale for detecting visual impairment in stroke admissions in the emergency department, with particular benefit in FAST-negative strokes. These findings support integrating a standardised screening checklist for visual impairment detection into emergency department stroke pathways.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Stroke, vision, visual impairment, V-FAST, National Institutes of Health Stroke Scale, emergency department, eye movements, visual fields, visual neglect, screening |
| Dates: | Date Event 14 May 2026 Published 14 May 2026 Published Online |
| Divisions: | Faculty of Health & Life Sciences Faculty of Health & Life Sciences > Inst. Life Courses & Medical Sciences Faculty of Health & Life Sciences > Inst. Life Courses & Medical Sciences > Inst. Life Courses & Medical Sciences (T&R staff) Faculty of Health & Life Sciences > Inst. Life Courses & Medical Sciences > Cardiovascular & Metabolic Medicine Faculty of Health & Life Sciences > Inst. Population Health Faculty of Health & Life Sciences > Inst. Population Health > Primary Care & Mental Health Faculty of Health & Life Sciences > Inst. Population Health > Inst. Population Health (T&R Staff) |
| Depositing User: | Symplectic Admin |
| Date Deposited: | 22 May 2026 08:42 |
| Last Modified: | 04 Nov 2026 14:09 |
| DOI: | 10.1177/02692155261450137 |
| Open Access URL: | https://journals.sagepub.com/doi/10.1177/026921552... |
| Related Websites: | |
| URI: | https://livrepository.liverpool.ac.uk/id/eprint/3198588 |
| Disclaimer: | The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate. |
Altmetric
Altmetric