Jinschek, Richard K, Wells, Jack, Robinson, Alex W, Gianni, Mario
ORCID: 0000-0001-5410-2377, Shen, Yao-Chun
ORCID: 0000-0002-8915-1993 and Browning, Nigel D
ORCID: 0000-0003-0491-251X
(2025)
Keywords
In: Atomic-scale Topographical Modeling of High-Resolution STEM Through-Focal Series Using Compressive Sensing.
|
Text
W4407222998.pdf - Unspecified Download (869kB) | Preview |
Abstract
Scanning transmission electron microscopy (STEM) is a powerful tool for imaging complex structures at atomic scale resolutions. Various imaging modalities such as Z-contrast imaging, electron energy loss spectroscopy, or 4D STEM can reveal spatial, chemical and electrical properties. One application, developed extensively by Ishikawa et. al. [1], uses a through focal series to recover atomic-scale topographical models. There are, however, potential difficulties in acquisition due to stability of both the sample and the microscope. One method which could relax the requirements is the use of compressive sensing, specifically probe subsampling. A subsampled image is formed by only positioning the electron probe at a subset of positions, therefore directly reducing the total electron fluence [2]. To form a topographical model from a focal series, the same field of view is exposed multiple times at high magnification. This can lead to beam damage as well as stage drift, meaning less certainty in the final measurements. Subsampling could both reduce the likelihood of beam damage, and the artefacts arising from sample drift. During a through-focal series we form a three-dimensional dataset, therefore data from a previous frame can be used to improve the data acquisition for the next [3]. This prior knowledge gives an idea of where the more important information such as the atomic sites or defects may be within the next image [4]. Therefore, rather than treating each new scan as a separate experiment, it would allow for a more informed sampling strategy. Since there is a minimal difference between the frames sampled, we can target our next sampling mask based on information from the previous frame (such as weighting the mask based on intensity).
| Item Type: | Conference Item (Unspecified) |
|---|---|
| Uncontrolled Keywords: | 51 Physical Sciences, 5104 Condensed Matter Physics, Bioengineering |
| Depositing User: | Symplectic Admin |
| Date Deposited: | 10 Sep 2026 11:13 |
| Last Modified: | 10 Sep 2026 12:16 |
| DOI: | 10.14293/apmc13-2025-0243 |
| Related Websites: | |
| URI: | https://livrepository.liverpool.ac.uk/id/eprint/3201848 |
| Disclaimer: | The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate. |
Altmetric
Altmetric