Development and Calibration of a Multizone CONTAM Model for Indoor PM2.5 Dynamics in Central Asian Social Housing Under High Ambient Pollution



Kurmanbekova, Mainur, Du, Jiangtao ORCID: 0000-0002-4307-4398 and Sharples, Steve ORCID: 0000-0002-6309-9672
(2026) Development and Calibration of a Multizone CONTAM Model for Indoor PM2.5 Dynamics in Central Asian Social Housing Under High Ambient Pollution APPLIED SCIENCES-BASEL, 16 (19). 9829-. ISSN 2076-3417, 2076-3417

[thumbnail of applsci-16-09829.pdf] PDF
applsci-16-09829.pdf - Open Access published version

Download (2MB) | Preview

Abstract

Featured Application: The calibrated model can evaluate retrofit and ventilation strategies to reduce indoor PM2.5 exposure in the studied social housing apartment and, with appropriate adaptation and calibration, in similar polluted urban settings. Indoor air quality in Central Asian social housing remains understudied despite high ambient air pollution and growing concern over housing-related health inequalities. This study developed and calibrated a multizone CONTAM model to simulate hourly indoor PM2.5 dynamics in a representative, naturally ventilated, occupied social housing apartment in Almaty, Kazakhstan, during the winter heating season. The model included measured outdoor PM2.5 concentrations, local meteorological data, construction drawings, literature-derived leakage values, and occupancy schedules based on household interviews. Calibration was performed iteratively across 360 model versions, and performance was evaluated using ASTM D5157-19 model-evaluation criteria. The final calibrated model met NMSE and FB (NMSE = 0.21, FB = 0.08) criteria with FS just outside the |FS| ≤ 0.50 limit (FS = −0.51), but not the correlation, slope or intercept criteria (r = 0.86, M = 0.66, b = 43% of the mean observed concentration). Baseline simulations showed significant spatial and seasonal variation in PM2.5 concentrations. During winter, simulated average PM2.5 concentrations were 41.81 µg/m3 in the living room and 220.59 µg/m3 in the kitchen, with cooking peaks exceeding 1000 µg/m3. Warmer season simulations indicated weaker stack-driven ventilation and greater interzonal pollutant transfer. These findings show that calibrated multizone modelling can characterize PM2.5 transport in occupied social housing and provide a basis for evaluating retrofit and policy interventions to reduce PM2.5 exposure among vulnerable populations.

Item Type: Article
Uncontrolled Keywords: indoor air quality, CONTAM, PM2.5, multizone modelling, model calibration, social housing, ASTM D5157-19, environmental health inequality, Kazakhstan
Dates:
Date
Event
3 October 2026
Published
3 October 2026
Published Online
30 September 2026
Accepted
Divisions: Faculty of Humanities & Social Sciences
Faculty of Humanities & Social Sciences > School of the Arts
Faculty of Humanities & Social Sciences > School of the Arts > Architecture
Faculty of Humanities & Social Sciences > Faculty of Humanities & Social Sci (All T&R Staff)
Faculty of Humanities & Social Sciences > School of the Arts > School of the Arts (T&R Staff)
Depositing User: Symplectic Admin
Date Deposited: 05 Oct 2026 07:33
Last Modified: 30 Oct 2026 09:20
DOI: 10.3390/app16199829
Related Websites:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3204322
Disclaimer: The University of Liverpool is not responsible for content contained on other websites from links within repository metadata. Please contact us if you notice anything that appears incorrect or inappropriate.