Feasibility of cardiovascular magnetic resonance derived coronary wave intensity analysis



Raphael, Claire E, Keegan, Jennifer, Parker, Kim H, Simpson, Robin, Collinson, Julian, Vassiliou, Vass, Wage, Ricardo, Drivas, Peter, Strain, Stephen, Cooper, Robert
et al (show 9 more authors) (2016) Feasibility of cardiovascular magnetic resonance derived coronary wave intensity analysis. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 18 (1). 93-.

Access the full-text of this item by clicking on the Open Access link.

Abstract

<h4>Background</h4>Wave intensity analysis (WIA) of the coronary arteries allows description of the predominant mechanisms influencing coronary flow over the cardiac cycle. The data are traditionally derived from pressure and velocity changes measured invasively in the coronary artery. Cardiovascular magnetic resonance (CMR) allows measurement of coronary velocities using phase velocity mapping and derivation of central aortic pressure from aortic distension. We assessed the feasibility of WIA of the coronary arteries using CMR and compared this to invasive data.<h4>Methods</h4>CMR scans were undertaken in a serial cohort of patients who had undergone invasive WIA. Velocity maps were acquired in the proximal left anterior descending and proximal right coronary artery using a retrospectively-gated breath-hold spiral phase velocity mapping sequence with high temporal resolution (19 ms). A breath-hold segmented gradient echo sequence was used to acquire through-plane cross sectional area changes in the proximal ascending aorta which were used as a surrogate of an aortic pressure waveform after calibration with brachial blood pressure measured with a sphygmomanometer. CMR-derived aortic pressures and CMR-measured velocities were used to derive wave intensity. The CMR-derived wave intensities were compared to invasive data in 12 coronary arteries (8 left, 4 right). Waves were presented as absolute values and as a % of total wave intensity. Intra-study reproducibility of invasive and non-invasive WIA was assessed using Bland-Altman analysis and the intraclass correlation coefficient (ICC).<h4>Results</h4>The combination of the CMR-derived pressure and velocity data produced the expected pattern of forward and backward compression and expansion waves. The intra-study reproducibility of the CMR derived wave intensities as a % of the total wave intensity (mean ± standard deviation of differences) was 0.0 ± 6.8%, ICC = 0.91. Intra-study reproducibility for the corresponding invasive data was 0.0 ± 4.4%, ICC = 0.96. The invasive and CMR studies showed reasonable correlation (r = 0.73) with a mean difference of 0.0 ± 11.5%.<h4>Conclusion</h4>This proof of concept study demonstrated that CMR may be used to perform coronary WIA non-invasively with reasonable reproducibility compared to invasive WIA. The technique potentially allows WIA to be performed in a wider range of patients and pathologies than those who can be studied invasively.

Item Type: Article
Uncontrolled Keywords: Aorta, Coronary Vessels, Humans, Heart Diseases, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging, Cine, Blood Flow Velocity, Calibration, Feasibility Studies, Reproducibility of Results, Predictive Value of Tests, Coronary Circulation, Adult, Middle Aged, England, Female, Male, Arterial Pressure, Breath Holding
Depositing User: Symplectic Admin
Date Deposited: 23 Jan 2019 14:56
Last Modified: 25 Mar 2024 22:34
DOI: 10.1186/s12968-016-0312-8
Open Access URL: https://jcmr-online.biomedcentral.com/track/pdf/10...
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3031695