Numerical Simulation of Corneal Fibril Reorientation in Response to External Loading



Zhou, Dong ORCID: 0000-0003-0129-4867, Abass, Ahmed ORCID: 0000-0002-8622-4632, Eliasy, Ashkan ORCID: 0000-0002-4473-1900, Movchan, Alexander, Movchan, Natalia ORCID: 0000-0001-9166-1952 and Elsheikh, Ahmed ORCID: 0000-0001-7456-1749
(2019) Numerical Simulation of Corneal Fibril Reorientation in Response to External Loading. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 16 (18). E3278-.

This is the latest version of this item.

[img] Text
Dong_ijerph_578817.pdf - Author Accepted Manuscript

Download (1MB) | Preview
[img] Text
ijerph-16-03278.pdf - Published version

Download (6MB) | Preview

Abstract

<h4>Purpose</h4>To simulate numerically the collagen fibril reorientation observed experimentally in the cornea.<h4>Methods</h4>Fibril distribution in corneal strip specimens was monitored using X-ray scattering while under gradually increasing axial loading. The data were analysed at each strain level in order to quantify the changes in the angular distribution of fibrils with strain growth. The resulting relationship between stain and fibril reorientation was adopted in a constitutive model to control the mechanical anisotropy of the tissue material. The outcome of the model was validated against the experimental measurements before using the model in simplified representations of two surgical procedures.<h4>Results</h4>The numerical model was able to reproduce the experimental measurements of specimen deformation and fibril reorientation under uniaxial loading with errors below 8.0%. With tissue removal simulated in a full eye numerical model, fibril reorientation could be predicted around the affected area, and this change both increased with larger tissue removal and reduced gradually away from that area.<h4>Conclusion</h4>The presented method can successfully simulate fibril reorientation with changes in the strain regime affecting cornea tissue. Analyses based on this method showed that fibrils tend to align parallel to the tissue cut following keratoplasty operations. With the ability to simulate fibril reorientation, numerical modelling can have a greater potential in modelling the behaviour following surgery and injury to the cornea.

Item Type: Article
Uncontrolled Keywords: tissue microstructure, numerical modelling, ocular biomechanics
Depositing User: Symplectic Admin
Date Deposited: 16 Sep 2019 10:47
Last Modified: 24 Jan 2024 19:26
DOI: 10.3390/ijerph16183278
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3054813

Available Versions of this Item