TRIFIC: The TRIUMF Fast Ion Counter



Chester, A, Smallcombe, J, Henderson, J, Berean-Dutcher, J, Bernier, N, Bhattacharjee, SS, Garnsworthy, AB, Georges, S, Gillespie, SA, Hackman, G
et al (show 5 more authors) (2019) TRIFIC: The TRIUMF Fast Ion Counter. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 930. pp. 1-7.

[img] Text
TRIFIC__The_TRIUMF_Fast_Ion_Counter.pdf - Author Accepted Manuscript

Download (3MB) | Preview

Abstract

The TRIUMF Fast Ion Counter (TRIFIC) is a tilted-grid gas counter detector for identifying the impurities in radioactive ion beams (RIBs). Placed at zero degrees downstream of a primary reaction target at the TRIUMF ISAC-II facility, TRIFIC provides accurate Z identification of beam species on an event-by-event basis at a rate of up to 5×10 5 particles per second and functions as a beam composition monitor at rates up to 5×10 7 particles per second. With this additional level of diagnostics, RIB experiments at TRIUMF are able to reach levels of sensitivity not previously possible. Details regarding the construction and instrumentation of TRIFIC as well as results from the commissioning of the detector are presented.

Item Type: Article
Uncontrolled Keywords: Gas detector, Ionization chamber, Radioactive ion beams, Particle identification
Depositing User: Symplectic Admin
Date Deposited: 12 Oct 2020 09:54
Last Modified: 18 Jan 2023 23:29
DOI: 10.1016/j.nima.2019.03.075