Dynamic analysis of a pumped-storage hydropower plant with random power load



Zhang, Hao, Chen, Diyi, Xu, Beibei, Patelli, Edoardo ORCID: 0000-0002-5007-7247 and Tolo, Silvia ORCID: 0000-0003-3547-7012
(2018) Dynamic analysis of a pumped-storage hydropower plant with random power load. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 100. pp. 524-533.

[img] Text
paperMSSPAuthorCopy.pdf - Author Accepted Manuscript

Download (2MB)

Abstract

This paper analyzes the dynamic response of a pumped-storage hydropower plant in generating mode. Considering the elastic water column effects in the penstock, a linearized reduced order dynamic model of the pumped-storage hydropower plant is used in this paper. As the power load is always random, a set of random generator electric power output is introduced to research the dynamic behaviors of the pumped-storage hydropower plant. Then, the influences of the PI gains on the dynamic characteristics of the pumped-storage hydropower plant with the random power load are analyzed. In addition, the effects of initial power load and PI parameters on the stability of the pumped-storage hydropower plant are studied in depth. All of the above results will provide theoretical guidance for the study and analysis of the pumped-storage hydropower plant.

Item Type: Article
Uncontrolled Keywords: Pumped-storage hydropower plant, Dynamic characteristics, Random load, Mathematical modeling
Depositing User: Symplectic Admin
Date Deposited: 11 Aug 2017 09:11
Last Modified: 19 Jan 2023 06:58
DOI: 10.1016/j.ymssp.2017.07.052
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3008906