Typical Localised Element-Specific Finite Element Anterior Eye Model



Towler, Joseph, Consejo, Alejandra, Zhou, Dong, Romano, Vito ORCID: 0000-0002-5148-7643, Levis, Hannah ORCID: 0000-0002-3923-1178, Boote, Craig, Elsheikh, Ahmed ORCID: 0000-0001-7456-1749, Geraghty, Brendan ORCID: 0000-0003-0561-6667 and Abass, Ahmed ORCID: 0000-0002-8622-4632
(2023) Typical Localised Element-Specific Finite Element Anterior Eye Model. Heliyon, 9 (4). e13944-.

[img] Text
Typical Localised Element-Specific Finite Element Anterior Eye Model.pdf - Author Accepted Manuscript

Download (4MB) | Preview

Abstract

<h4>Purpose</h4>The study presents an averaged anterior eye geometry model combined with a localised material model that is straightforward, appropriate and amenable for implementation in finite element (FE) modelling.<h4>Methods</h4>Both right and left eye profile data of 118 subjects (63 females and 55 males) aged 22-67 years (38.5 ± 7.6) were used to build an averaged geometry model. Parametric representation of the averaged geometry model was achieved through two polynomials dividing the eye into three smoothly connected volumes. This study utilised the collagen microstructure x-ray data of 6 ex-vivo healthy human eyes, 3 right eyes and 3 left eyes in pairs from 3 donors, 1 male and 2 females aged between 60 and 80 years, to build a localised element-specific material model for the eye.<h4>Results</h4>Fitting the cornea and the posterior sclera sections to a 5th-order Zernike polynomial resulted in 21 coefficients. The averaged anterior eye geometry model recorded a limbus tangent angle of 37° at a radius of 6.6 mm from the corneal apex. In terms of material models, the difference between the stresses generated in the inflation simulation up to 15 mmHg in the ring-segmented material model and localised element-specific material model were significantly different (p < 0.001) with the ring-segmented material model recording average Von-Mises stress 0.0168 ± 0.0046 MPa and the localised element-specific material model recording average Von-Mises stress 0.0144 ± 0.0025 MPa.<h4>Conclusions</h4>The study illustrates an averaged geometry model of the anterior human eye that is easy to generate through two parametric equations. This model is combined with a localised material model that can be used either parametrically through a Zernike fitted polynomial or non-parametrically as a function of the azimuth angle and the elevation angle of the eye globe. Both averaged geometry and localised material models were built in a way that makes them easy to implement in FE analysis without additional computation cost compared to the limbal discontinuity so-called idealised eye geometry model or ring-segmented material model.

Item Type: Article
Uncontrolled Keywords: Eye model, Localised eye, Ideal eye, Average eye, Mathematical model
Divisions: Faculty of Health and Life Sciences
Faculty of Health and Life Sciences > Institute of Life Courses and Medical Sciences
Faculty of Science and Engineering > School of Engineering
Depositing User: Symplectic Admin
Date Deposited: 03 Mar 2023 08:17
Last Modified: 13 Jun 2023 05:12
DOI: 10.1016/j.heliyon.2023.e13944
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3168710