Highly Reliable Back-to-Back Power Converter Without Redundant Bridge Arm for Doubly Fed Induction Generator-Based Wind Turbine



Ni, Kai ORCID: 0000-0002-7467-2921, Hu, Yihua ORCID: 0000-0002-1007-1617, Lagos, Dimitris T, Chen, Guipeng, Wang, Zheng and Li, Xinhua
(2019) Highly Reliable Back-to-Back Power Converter Without Redundant Bridge Arm for Doubly Fed Induction Generator-Based Wind Turbine. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 55 (3). pp. 3024-3036.

[img] Text
08611221Kai Ni_Early_Highly Reliable Back-To-Back Power Converter without Redundant Bridge Arm for Doubly-Fed Induction Generator-Based Wind Turbine.pdf - Author Accepted Manuscript

Download (1MB) | Preview

Abstract

In this paper, a highly reliable back-to-back (BTB) power converter is proposed for doubly fed induction generator-based wind turbines (DFIG-WTs). When a power switch open-circuit fault is encountered in either the grid-side converter (GSC) or the rotor-side converter (RSC), a four-switch three-phase (FSTP) topology is formed to avoid using redundant bridge arms, which reduces the power circuit complexity and minimizes the conduction and switching losses. A simplified space vector pulsewidth modulation technique is used to eliminate sector identification and complex trigonometric calculations. In addition, the influence of dc-bus capacitor voltage unbalance on the electromagnetic torque is analyzed in detail. The offset current components are calculated, and they are deducted from the reference values in the modified control strategies to suppress the dc-bus voltage deviation. Moreover, the power loss model of a BTB converter is analyzed in detail, and the efficiency study is performed in various post-fault situations. Simulations in MATLAB/Simulink are carried out to verify the performance of a DFIG-WT based on a FSTP BTB converter. Furthermore, the control hardware-in-the-loop setup with RSC and GSC separately simulated in a digital real-time simulator is applied for experimental verification of the proposed control strategy.

Item Type: Article
Uncontrolled Keywords: Back-to-back (BTB) converter, control hardware in the loop (CHIL), dc-bus voltage unbalance, doubly fed induction generator-based wind turbine (DFIG-WT), efficiency study, four-switch three-phase (FSTP)
Depositing User: Symplectic Admin
Date Deposited: 08 May 2019 08:19
Last Modified: 19 Jan 2023 00:49
DOI: 10.1109/TIA.2019.2892925
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3040202