The impact of 3D stereoscopic visualisation on performance in electron skin apposition techniques using VERT



Parker, Ellis, Kirby, Mike ORCID: 0000-0001-9765-5641 and Bridge, Pete ORCID: 0000-0001-7704-9812
(2023) The impact of 3D stereoscopic visualisation on performance in electron skin apposition techniques using VERT. Journal of Radiotherapy in Practice, 22 (1). e95-.

[img] Text
EP MCK PB Manuscript Revised for UoL Elements.pdf - Author Accepted Manuscript

Download (456kB) | Preview

Abstract

<jats:title>Abstract</jats:title> <jats:sec id="S1460396923000158_as1"> <jats:title>Introduction:</jats:title> <jats:p>The Virtual Environment for Radiotherapy Training (VERT) is a simulator used to train radiotherapy students cost-effectively with limited risk. VERT is available as a two-dimensional (2D) and a more costly three-dimensional (3D) stereoscopic resource. This study aimed to identify the specific benefits afforded by stereoscopic visualisation for student training in skin apposition techniques.</jats:p> </jats:sec> <jats:sec id="S1460396923000158_as2"> <jats:title>Method:</jats:title> <jats:p>Eight participants completed six electron skin apposition setups in both 2D and 3D views of VERT using a 7 cm × 10 cm rectangular applicator setup to 100 cm focus skin distance (FSD). The standard deviation (SD) of the mean distance from each corner of the applicator to the virtual patient’s skin surface [which we define as apposition precision (AP)] was measured along with the time taken to achieve each setup. Participants then completed a four-question Likert-style questionnaire concerning their preferences and perceptions of the 2D and 3D views.</jats:p> </jats:sec> <jats:sec id="S1460396923000158_as3"> <jats:title>Results:</jats:title> <jats:p>There was little difference in mean setup times with 218·43 seconds for 2D and 211·29 seconds for 3D (3·3% difference). There was a similarly small difference in AP with a mean SD of 5·61 mm for 2D and 5·79 mm for 3D (3·2% difference) between views. The questionnaire results showed no preference for the 3D view over the 2D.</jats:p> </jats:sec> <jats:sec id="S1460396923000158_as4"> <jats:title>Conclusion:</jats:title> <jats:p>These findings suggest that the 2D and 3D views result in similar setup times and precision, with no user preference for the 3D view. It is recommended that the 2D version of VERT could be utilised in similar situations with a reduced logistical and financial impact.</jats:p> </jats:sec>

Item Type: Article
Uncontrolled Keywords: VERT, skin apposition, precision, stereoscopic, 3D
Divisions: Faculty of Health and Life Sciences
Faculty of Health and Life Sciences > Institute of Population Health
Faculty of Health and Life Sciences > Institute of Population Health > School of Health Sciences
Depositing User: Symplectic Admin
Date Deposited: 03 May 2023 07:46
Last Modified: 14 Mar 2024 20:06
DOI: 10.1017/s1460396923000158
Related URLs:
URI: https://livrepository.liverpool.ac.uk/id/eprint/3170105